Scientific Herald of Uzhhorod University. Series "Physics"

ISSN 2415-8038 e-ISSN 2786-6688
  • Home
  • Articles & Issues
    • Current
    • All Issues
  • About
    • Aims and Scope
    • Editorial Board
    • Indexing
    • Sources of Financing
  • For Authors
    • Submission
    • Terms of Publication
    • Formatting Guidelines
    • Peer Review Process
    • Article Processing Charges
    • License Agreement
  • Ethics & Policies
    • Publication Ethics
    • Conflict of Interest
    • Subscription Policy
    • Archiving
    • Complaints Policy
    • Privacy Statement
    • Corrections and Retractions
    • Anti-plagiarism Policy
    • Generative AI Policy
  • Search
  • Contacts

Scientific Herald of Uzhhorod University. Series "Physics"

  • Submit an article
  • Home
  • Articles & Issues
    • Current
    • All Issues
  • About
    • Aims and Scope
    • Editorial Board
    • Indexing
    • Sources of Financing
  • For Authors
    • Submission
    • Terms of Publication
    • Formatting Guidelines
    • Peer Review Process
    • Article Processing Charges
    • License Agreement
  • Ethics & Policies
    • Publication Ethics
    • Conflict of Interest
    • Subscription Policy
    • Archiving
    • Complaints Policy
    • Privacy Statement
    • Corrections and Retractions
    • Anti-plagiarism Policy
    • Generative AI Policy
  • Search
  • Contacts

Measurement of the absolute value of exposure dose on the betatron B-25

Issue 42, 2017

Ivan, V.O. Martyshychkin, R.M. Plekan, O.G. Okunev,

10.24144/2415-8038.2017.42.196-201

Abstract

Radiobiological research, treatment of malignant tumors, acceleration of chemical processes, study of radiation defects, metal defectoscopy are some main problems requiring radiation exposure. In this regard, the primary task for accelerators of charged particles is to determine the dose of radiation. Among the many types of charged particle accelerators for scientific and practical purposes, an induction electronic accelerator plays a special role. In betatron, an electric field is used to accelerate electrons in a circular orbit, the intensity of which is replaced by a magnetic flux. This article proposes one of the methods for measuring the exposure dose during operation of betatron B-25. In order to control the beam of bremsstrahlung, a passage ionization chamber, an absolute ionization chamber, two ball cameras of the clinical dosimeter RTF27012 are used in the experiment. The passage camera's values are proportional to the exposure dose, and the ball camera's values are proportional to the intensity of the electron beam. The ball cameras are independently calibrated with standard reference sources of beta particles and gamma quanta (complete of clinical dosimeter). A table of calibration of particles passing through the passage chamber and an absolute accelerator chamber is created. The value of the exposure dose in the experiment is obtained

Keywords: betatron, passage chamber, absolute chamber, target, calibration, intensity, x-ray, dose

Suggested citation

Haysak, I., V.O. Martyshychkin, R.M. Plekan, O.G. Okunev, & M.T. Sabolchiy (2017).

Measurement of the absolute value of exposure dose on the betatron B-25

. Scientific Herald of Uzhhorod University. Series "Physics", (42), 196-201. 10.24144/2415-8038.2017.42.196-201